If you go up a cooling tower, its best to not go alone. There are 6 cooling towers. Cooling Tower #1 is redudancy and Cooling Tower 6 had a blade that failed due to unbalance. So 4 cooling towers are in operations all the time. We had a discussion to
Essential Technical Books for me
Keeping up to date with many fields of study
Just got this in the mail recently. In order to understand criticality rankings, its good to get a good grasp on Reliability as a whole. In the next couple of years I need to have a strong base on all of these fields: 1. Thermography 2. Vibration 3. Ultrasound (All
Thermography training at Rockwell
Today we had a training session on thermography. The most important part of the session was the hands-on. Once we got started, the first panel we opened had a thermal anomaly. Before the images above we actually measured 164degC. This is why Proactive Maintenance principles need to be applied before
Rockwell Pump Room 9/12/2025
We were taken the pump room for the first time, 2nd floor. Engr. Jim told me about these 4 pumps. It seems like there are pressure issues due to failure of some components. The tenants upstairs experience a drop in water pressure as a result. He told me the right
Finding a leak on a Chiller System 9.12.2025
The Rockwell manager Jim mentioned in a meeting that two of their chiller systems (2 & 3) have experienced leaks. This is after I presented to their management our Condition based monitoring activities in the facility. Chillers usually don't need to refill R134 for a decade. But 2
Solar Projects and Energy Auditing
July 15, 2025 Will have a zoom call with La Sagesse, Rehab Center for their PV solar system. Propose a 40kW system. This is has been in the works since 2023. Funding is an issue. The Sisters had to fund raise. The Church has decided to fund the rest. It&
Rockwell Motor and Pump Inspections
On June 5, 2025 conducted a ultrasound and vibration inspection on all the available motors and pumps. Looking at the data was very interesting, full of sound and vibration. Both provide a TWF and FFT, but the point that these two data sets bifurcate is the fault frequency signature. Ultrasound
Ultrasound and Thermographic inspection of Rockwell Power Plant
I'm not making this post to report a finding or realization. It is to just note that I completed a partial inspection of the Rockwell Power Plant chiller system. I have inspected Chiller 2, 3, 4, and 6. I only inspected those motors and pumps and did not